App2-2 Appendix 2 n : 1 Connection (Multi-link 2)
This multi-link connection is available with almost all the PLC models that support 1 : 1 connection
(refer to the “Appendix”).
(The connection between the master station and the PLC is the same as the one for 1 : 1
connection.)
Use the RS-485 2-wire connection between stations of the V7 series. Please use Hakko
Electronics’ multi-link 2 master cable (V6-MLT) for connection between the master station (local
port 1) and the slave station (local port 2).
In the following cases, multi-link 2 connection is not available.
1. A communication interface unit (example: OPCN-1, CC-LINK, Ethernet, etc) is used.
2. The V6 series (master or slave station) is used for the temperature control network or
PLC2Way function.
The V7 and V6 series can be used together. The V6 series can be the master station.
(However, when V606/V606i is the master station, the slave station must be V606/V606i. Also,
depending on the hardware version of the V6 series, multi-link 2 connection may not be supported.
Refer to the V6 Hardware Specifications.)
Wiring
Connection
For V7 Series:
(a) Connection between PLC V7 master station
The communication parameter setting and connecting method are the same as those for 1 : 1
connection.
(Refer to “Chapter 2” to “Chapter 33.”)
(b)(c) Connection between V7 series master station V7 slave station
The connecting port for the V7 series master station depends on the selection for [Multi-Link]
(either [Modular Jack 1] or [Modular Jack 2]) on the V-SFT editor. Selection of [Modular Jack
2] is recommended. ([Editor Port] is set as default for [Modular Jack 1].)
The connecting port of the V7 series slave station should be CN1. It is recommended that
CN1 be equipped with a terminal converter “TC485” (set to 2-wire connection).
The multi-link 2 master cable (b) (V6-MLT) is 3 m long.
If the distance (c) between the V7 series master station and the V7 series slave station is
longer than 3 m, use a terminal block and connect the cables.
(d)(e) Connection between V7 series slave station V7 slave station
Use the RS-485 2-wire connection.
It is recommended that CN1 be equipped with a terminal converter “TC485” (set to 2-wire
connection).
(b)(c)(d)(e) The maximum length between V7 series should be 500 m.
* To avoid line-noise problems, connect one terminal only so that the shielded frame ground of each
cable will not be connected between the V7 series.
The shielded frame ground of V6-MLT must be connected to the V7 series master station.
PLC
CN1CN1 MJ2
(a)
(b)
(c)
(d) (e)
CN1CN1
Communications between V7 series: RS-485 (2-wire), maximum length = 500 m
V7 master station
(= Local Port 1)
V7 slave station
(= Local Port 2)
V7 slave station
(= Local Port 3)
V7 slave station
(= Local Port 4)
Te rm i na l
block
Vedere la pagina 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 331 332

Commenti su questo manuale

Nessun commento

Agilent Technologies 54622D manuels

Manuels d'utilisation et guides de l'utilisateur pour Mesure, test et contrôle Agilent Technologies 54622D.
Nous fournissons des manuels en pdf 1 Agilent Technologies 54622D à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Mesure, test et contrôle Agilent Technologies

Modèles Type de document
75000 SERIES B Spécifications   Agilent Technologies 75000 SERIES B Specifications, 24 pages
22A Spécifications   Agilent Technologies 22A Specifications, 120 pages
N9344C Spécifications   Agilent Technologies N9344C Product specifications [en] , 24 pages
8000 Series Spécifications   Agilent Technologies 8000 Series Specifications, 162 pages
81134A Guide de l'utilisateur   Agilent Technologies 81134A User`s guide, 92 pages
E6640A EXM Manuel de l'utilisateur   Solve today, evolve tomorrow, 23 pages
L4400 Manuel de l'utilisateur   AGILENT TECHNOLOGIES 44478A, 20 pages
DC110 Manuel de l'utilisateur   Agilent 4294A Precision Impedance Analyzer, 40 Hz to [en] , 8 pages
86100C Manuel de service   Agilent Technologies 86100C Technical data, 28 pages
B2902 Manuel de l'utilisateur   Produkt-Datenblatt, tech. Daten, 35 pages
HP 54601B Guide de l'utilisateur   Agilent Technologies HP 54601B User`s guide, 123 pages
Ininiium 9000 Spécifications   Agilent Technologies Ininiium 9000 Specifications, 166 pages
77-4 Guide de l'utilisateur   Agilent Technologies 77-4 User`s guide, 224 pages
InfiniiVision 3000 3024A MSO-X Spécifications   Agilent Technologies InfiniiVision 3000 3024A MSO-X Specifications, 37 pages
L4400 Guide de l'utilisateur   Agilent Technologies L4400 User`s guide, 281 pages
E8364C Guide de l'utilisateur   Agilent Technologies E8364C User`s guide, 44 pages
E6630A Manuel de l'utilisateur   Keysight Technologies | EXM Wireless Test Set E6640A, 24 pages
InfiniiVision 7000B Series Guide de l'utilisateur   Agilent Technologies InfiniiVision 7000B Series User`s guide, 428 pages
54502A Manuel de service   Agilent Technologies 54502A Service manual, 111 pages
42A Guide de l'utilisateur   Agilent Technologies 42A User`s guide, 194 pages